Back to top
Labomed Inc. GC 46 Electronic Pressure Flow Monitoring Gas Chromatography , For Laboratory Use
Labomed Inc. GC 46 Electronic Pressure Flow Monitoring Gas Chromatography , For Laboratory Use

Labomed Inc. GC 46 Electronic Pressure Flow Monitoring Gas Chromatography , For Laboratory Use

Price 50000.0 INR/ Piece

MOQ : 1 Piece

Labomed Inc. GC 46 Electronic Pressure Flow Monitoring Gas Chromatography , For Laboratory Use Specification

  • Heating Capacity
  • Up to 400C
  • Power Supply
  • AC Mains
  • Features
  • Electronic pressure and flow monitoring, advanced temperature programming, safety interlocks, auto diagnostic, column oven
  • Control Type
  • Microprocessor-based digital control
  • Temperature Resistance
  • Ambient to 400C
  • Accuracy
  • Pressure/Flow: 1% FS, Temperature: 0.1C
  • Shape
  • Rectangular
  • Display Type
  • Digital LCD Display
  • Type
  • Gas Chromatography (GC) System
  • Dimension (L*W*H)
  • 600 x 500 x 450 mm
  • Equipment Type
  • Electronic Pressure Flow Monitoring Gas Chromatograph
  • Equipment Materials
  • Powder coated metal body, stainless steel panels
  • Power
  • 300 W
  • Voltage
  • 220-240 V AC, 50/60 Hz
  • Material
  • Metal and stainless steel
  • Application
  • Laboratory Analysis of Gaseous and Liquid Samples
  • Safety Features
  • Over-temperature protection, leak alarm, power failure memory
  • Flow Control
  • Electronic Pressure Control (EPC)
  • Number of Injection Ports
  • 2
  • Ambient Operating Range
  • 15C to 35C
  • Data Output
  • USB and RS232 connectivity, compatible with chromatography software
  • Display Interface
  • Graphical LCD with keypad
  • Detector Options
  • FID, TCD, ECD, NPD, FPD
  • Compliance
  • GLP/GMP compliant
  • Sample Injection System
  • Manual and Auto-injector compatible
  • Column Oven Temperature Programming
  • Multi-step programmable ramp system
 
 

About Labomed Inc. GC 46 Electronic Pressure Flow Monitoring Gas Chromatography , For Laboratory Use

Product Details :
GC 46
gas chromatography is a new generation of gas chromatograph with high stability and reliability, which is suitable for routine testing. It is equipped with advanced electronic pressure and flow measurement monitoring EPFM module, by adjusting gas circuit knob, can get gas parameters easily in the host screen and workstation, including the pressure and flow of carrier gas, hydrogen, air etc, and the injection port diversion ratio, column flow, etc. No flow meter measurement and manual calculation required, easy to operate.

GC-46 gas chromatography is widely used in petrochemical, fine chemical, biological medicine, environmental protection, food hygiene, high purity gas, electricity, winemaking, scientific research and education and other fields of analysis, is the best choice for daily detection.

The machine can be installed at most three injection ports and three detectors; Easy to install automatic liquid sampler and special custom valve system to achieve high throughput analysis.

GC-46 series networked gas chromatography can be equipped with 6 bit, 15 bit, and 150 bit liquid automatic sampler and each parameter can be controlled by counter control software, which will bring better repeatability and improve work efficiency while eliminating errors caused by the manual injection.Features & Technical Parameters

Features & Technical ParametersFeatures & Technical Parameters
  • Features & Technical Parameters
  • 5.7-inch dot-matrix LCD large liquid display, support Chinese and English switch.
  • Gas circuit manually control electronic pressure flow monitoring, networking communication (Ethernet interface IEEE802.3), computer online full control operation.
  • SE series models adopt 1/16in imported stainless steel pipelines and stainless steel joints; The sample inlet and the vaporization chamber of the detector are specially treated to minimize the dead volume of the sample and the adsorption of the tube wall on the sample. With electronic flow monitoring, economic and practical, intuitive and convenient operation
  • All detectors and injection ports can be equipped with 5.7-inch dot-matrix LCD large liquid display, support Chinese and English switch.
  • Manual gas circuit control pressure and flow display: electronic pressure and flow measurement display, and can display pressure and flow in the anti-control software.
  • Full electronic pressure and flow measurement system: maximum number of measurement channels is 16.



Advanced Electronic Pressure Control

The GC 46 utilizes electronic pressure control (EPC) to precisely manage gas flow through the system, ensuring reliable and consistent chromatographic results. Its multi-step programmable oven allows for intricate temperature profiling, vital for complex sample separation. With an accuracy of 1% FS for pressure/flow and 0.1C for oven temperature, users benefit from exceptional analytical precision.


Flexible Detection and Injection Options

Users can tailor the GC 46 for specific laboratory needs with multiple detector options such as FID, TCD, ECD, NPD, and FPD. Supporting both manual and auto-injector systems, and equipped with two injection ports, the GC 46 accommodates a wide range of sample types and analysis workflows, increasing throughput and versatility.


User-Friendly Interface and Data Management

A graphical LCD with keypad provides a clear, intuitive interface for system control and monitoring. With connectivity options including USB and RS232, the GC 46 integrates smoothly with chromatography software for efficient data acquisition and analysis, enhancing laboratory productivity and data traceability.

FAQ's of Labomed Inc. GC 46 Electronic Pressure Flow Monitoring Gas Chromatography , For Laboratory Use:


Q: How does the GC 46 Electronic Pressure Flow Monitoring Gas Chromatograph enhance laboratory analysis accuracy?

A: The GC 46 achieves enhanced accuracy through its electronic pressure control (EPC) and advanced digital temperature programming, which precisely maintain flow rates and oven temperatures. This ensures repeatable, reliable chromatographic results, vital for high-quality laboratory analysis.

Q: What types of detectors are compatible with the Labomed GC 46, and how does this benefit users?

A: The GC 46 supports FID, TCD, ECD, NPD, and FPD detectors, allowing users to select the optimal detection method for their specific analysis. This versatility broadens the instrument's application range, making it suitable for diverse laboratory requirements.

Q: When should a laboratory consider using the auto-injector feature on the GC 46?

A: The auto-injector is recommended when handling high-throughput sample analysis or for improved consistency during repetitive testing. It automates injections, reduces operator errors, and improves result reproducibility, particularly in routine or large-batch analyses.

Q: Where does the GC 46 store and output analytical data, and how is it integrated with data management systems?

A: The GC 46 offers USB and RS232 connectivity for direct data output to compatible chromatography software. This facilitates seamless integration into existing laboratory data management systems, ensuring efficient storage and retrieval of analytical results.

Q: What procedures are in place to ensure safety during GC 46 operation?

A: Safety features include over-temperature protection, leak alarms, and power failure memory. These help safeguard users and data by providing automatic shutdowns and alerts in the event of abnormal conditions, ensuring laboratory and operator protection.

Q: How is the GC 46 suitable for both gaseous and liquid sample analysis?

A: With its versatile injection systems, programmable oven temperature range (ambient to 400C), and precise electronic controls, the GC 46 can efficiently analyze both gaseous and liquid samples, making it suitable for a wide spectrum of laboratory applications.

Q: What are the main benefits of the microprocessor-based digital control of the GC 46?

A: The microprocessor-based control offers high precision, automated diagnostics, and consistent regulation of key parameters, reducing manual intervention and error. This leads to superior analytical performance and minimized downtime, ultimately boosting laboratory efficiency.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lab Equipment Category

GAS CHROMATOGARPHY & GENERATORS

GAS CHROMATOGARPHY & GENERATORS

Price 415000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Shape : Rectangular

Dimension (L*W*H) : 410 x 320 x 250 mm

Temperature Resistance : 20C to 200C

Equipment Type : Gas Generator

Exhaust System

Exhaust System

Minimum Order Quantity : 1 Unit

Shape : Rectangular

Dimension (L*W*H) : 1200mm x 600mm x 900mm

Temperature Resistance : Up to 200C

Equipment Type : Ventilation & Extraction

CYCLINDER MANIFOLD SYSTEM

CYCLINDER MANIFOLD SYSTEM

Price 4800.0 INR / Piece

Minimum Order Quantity : 1 Piece

Shape : Rectangular/Linear as per Installation

Dimension (L*W*H) : Custom as per cylinder capacity and installation requirement

Temperature Resistance : 10C to +60C

Equipment Type : HighPressure Gas Distribution System

Digital Laboratory Gas Control System

Digital Laboratory Gas Control System

Price 2000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Shape : Rectangular

Dimension (L*W*H) : 450 mm x 300 mm x 180 mm

Temperature Resistance : Up to 60C

Equipment Type : Gas Control System