HCL Gas Pressure Regulator for Laboratory Specification

  • Display Type
  • Analog Pressure Gauge
  • Control Type
  • Manual
  • Shape
  • Cylindrical
  • Features
  • Corrosion Resistant, Leak Proof, Precise Pressure Control
  • Temperature Resistance
  • Up to 60C
  • Accuracy
  • 0.1 bar
  • Type
  • Single Stage Laboratory Gas Pressure Regulator
  • Dimension (L*W*H)
  • 170 x 120 x 150 mm (Approx.)
  • Equipment Type
  • Gas Pressure Regulator
  • Equipment Materials
  • Body: Brass / Stainless Steel
  • Material
  • Brass / Stainless Steel
  • Application
  • Laboratory use for HCL gas cylinders
  • Mounting
  • Cylinder Mounted
  • Outlet Pressure Range
  • 0-2 bar (adjustable)
  • Diaphragm Material
  • PTFE / Neoprene
  • Regulator Stage
  • Single Stage
  • Weight
  • Approx. 1.2 kg
  • Inlet Pressure Range
  • 0-7 bar (max)
  • Finish
  • Polished / Chrome Plated
  • Media Handling
  • Suitable for HCL and other corrosive gases
  • Connection Size
  • 1/4" BSP (F)
 

HCL Gas Pressure Regulator for Laboratory Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 5-7 Days
 

About HCL Gas Pressure Regulator for Laboratory

S.K. Instruments are one of the reputed Manufacturer of a vast range of P.P. Fume Hood, AAS Exhaust Fan, Gas Chromatography, P.P. Boiler, Lab Furnitures & Fittings, Ultra Sonicator, Gas Purification Control System and much more.

Precise Pressure Control for Laboratory Safety

Engineered specifically for laboratory environments, this single-stage gas pressure regulator ensures accurate and stable delivery of HCL and other corrosive gases. The adjustable outlet pressure (0-2 bar) and fine-tuned analog gauge enable researchers to maintain consistent gas flow parameters, safeguarding sensitive experiments and improving reproducibility.


Corrosion-Resistant Construction for Longevity

Utilizing a combination of brass or stainless steel for the main body and a PTFE or neoprene diaphragm, the regulator boasts robust resistance against the harsh effects of corrosive gases. Its cylinder-mounted design and chrome-plated or polished finish further enhance durability, making it ideal for extended laboratory use.

FAQ's of HCL Gas Pressure Regulator for Laboratory:


Q: How do I install the HCL gas pressure regulator onto a laboratory gas cylinder?

A: The regulator is designed for cylinder mounting using its 1/4" BSP (F) connection. Ensure the cylinder is closed, align the regulator fitting with the cylinder outlet, and securely tighten. Always verify connections are leak-proof before use.

Q: What materials make this gas pressure regulator suitable for corrosive gases like HCL?

A: The regulator's body is manufactured from either brass or stainless steel, paired with a PTFE or neoprene diaphragm, both of which exhibit excellent chemical resistance to harsh gases like hydrochloric acid.

Q: When should I adjust the outlet pressure, and how do I do it?

A: Adjust the outlet pressure when you need to achieve specific experimental conditions. This is done manually by turning the regulator's pressure control knob while monitoring the analog gauge, which displays values up to 2 bar for precise adjustments.

Q: Where is this gas pressure regulator typically used in laboratories?

A: This regulator is specifically designed for laboratory use with HCL gas cylinders but is also suitable for other corrosive gases, serving applications that demand precise and safe gas delivery within chemical, analytical, or research labs.

Q: What is the process for routine maintenance of the regulator?

A: Routine maintenance involves periodically inspecting for leaks, checking the diaphragm and seals, cleaning the external surfaces, and ensuring the analog gauge remains accurate. Always perform checks when the regulator is disconnected from gas supply.

Q: What benefits does the single-stage design provide?

A: A single-stage regulator provides quick pressure reduction in one step, which is ideal for applications where inlet pressure does not fluctuate significantly. This ensures rapid and precise control, ideal for controlled laboratory environments.

Q: How does the regulator ensure safety and accuracy during gas handling?

A: Its construction delivers reliable leak-proof performance and precise control (with 0.1 bar accuracy). Corrosion-resistant materials and a temperature rating up to 60C enhance safe, dependable operation in rigorous laboratory conditions.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Lab Equipment Category

Industrial Scrubber System

Industrial Scrubber System

Price 230000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : Customizable as per client requirements

Equipment Materials : Mild Steel, FRP, PP, SS316 as per application

Material : Mild Steel with FRP/PP Lining

Control Type : Automatic/Manual

PP BLOWER 1HP

PP BLOWER 1HP

Price 28000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : As per requirement/Standard size

Equipment Materials : Polypropylene (PP)

Material : Polypropylene (PP)

Control Type : On/Off switch

FLAMMABLE SOLVENTS STORAGE CABINETS

FLAMMABLE SOLVENTS STORAGE CABINETS

Price 170000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 1090 x 460 x 1650 mm

Equipment Materials : Doublewalled 18gauge steel

Material : Powdercoated Steel

Control Type : Manual

High Pressure Gas Manifold System , Capacity: 2 x 2 Cylinde

High Pressure Gas Manifold System , Capacity: 2 x 2 Cylinde

Price 5500.0 INR / Piece

Minimum Order Quantity : 1 Piece

Dimension (L*W*H) : Custom or as per requirement (typical for 2 x 2 cylinder system: approx. 1200mm x 400mm x 600mm)

Equipment Materials : Stainless Steel (SS 304/316), Brass (for some fittings)

Material : Stainless Steel, Brass

Control Type : Manual Changeover